Latest Connectors, Wire & Cable Technical Articles

Categories

Negative Effects of Grounding (Earthing) a DC Power Supply

Negative Effects of Grounding (Earthing) a DC Power Supply

DC voltage systems exist to provide controllers and field devices with stable power, but it is not always clear when these systems should be bonded with the earth ground of the AC line voltage supply.


Working With Legacy Systems—Why Use Serial to Ethernet Converters?

Working With Legacy Systems—Why Use Serial to Ethernet Converters?

One common challenge when working with legacy control systems is establishing communication with old devices that use old protocols like RS232 and RS485. Learn about the importance of converting from serial to Ethernet.


Configuring a Network With Pneumatic Valve Manifolds

Configuring a Network With Pneumatic Valve Manifolds

There are many distributed fieldbus capabilities for valve manifolds that can save on network overhead and wiring. In this article, we will look at PLC programming of fieldbus manifolds highlighting Festo's CPX layout.


Getting Starting with the HART Protocol for Sensing Instruments

Getting Starting with the HART Protocol for Sensing Instruments

The HART protocol enables instruments to send analog and digital signals over the same physical wire. This provides multiple advantages for remote configuration, increased accuracy, and more.


Power for Control Circuits: It’s Not Just Power Supplies

Power for Control Circuits: It’s Not Just Power Supplies

Power supplies tend to get a reputation as one of the most important power considerations of a DC control circuit - but we can’t ignore other key players: power filters, converters, and backup power modules.


Controlling Hydraulic Devices with Open and Closed Loop Systems

Controlling Hydraulic Devices with Open and Closed Loop Systems

What if you could control the end position and the speed of a hydraulic actuator accurately with just a simple signal? Some systems use simple open/close valves, but others require far more precision.


The Cat’s Out of the Bag - Demystifying Network Cables

The Cat’s Out of the Bag - Demystifying Network Cables

What’s the difference between a Cat 6 and a Cat 6a cable, anyhow? Ethernet cables must meet certain performance standards, and these standards can be quite confusing at first glance.


Up Close and Personal With Automated Ag Equipment

Up Close and Personal With Automated Ag Equipment

Our Control Automation engineering staff got the chance to visit a commercial farm in North Dakota and learn the hardware and software making these huge automated tractors ready for high-tech ‘field’ work.


How to Use Analog to Digital Converters in a Control System

How to Use Analog to Digital Converters in a Control System

Using an ADC can be very useful when dealing with analog devices in microprocessors, and a necessity when adding analog devices to an industrial controller. But once you connect the hardware - what next?


Dynamic Braking Resistors for Motor Control Applications

Dynamic Braking Resistors for Motor Control Applications

Large DC and AC motor drives often provide terminals for installing a braking resistor. What are these resistors, and how do they slow down a machine? What hazards and cautions must be considered?


Introduction to Safety Relays

Introduction to Safety Relays

Redundancy and safety are often seen together in industrial safety systems. Safety relays monitor emergency devices to switch contacts based on status - but what makes them different from normal relays?


How-To: Programming with IO-Link Devices

How-To: Programming with IO-Link Devices

Advanced features such as programmable limits, diagnostics, and remote configuration are available with IO-Link devices. Learn how to connect an example IO-Link block into an actual PLC project.


Info Byte: Preventing Relay Burnout with Flyback Diodes

Info Byte: Preventing Relay Burnout with Flyback Diodes

Inductive loads, such as solenoids and contactors, can cause arcs and failures back into electromechanical switching devices, causing costly downtime. The solution is cheaper than you think.


Combating That Killer of Industrial Pneumatic Systems - Water

Combating That Killer of Industrial Pneumatic Systems - Water

Moisture inside industrial pneumatic systems is a major cause for concern, and if the air is not filtered or dried properly, it can lead to serious failures.


Choosing The Right Cables for Industrial Automation

Choosing The Right Cables for Industrial Automation

Industrial automation is only possible when the various system components can communicate with each other using physical cable connections. In this article, learn about some of the most popular communication cables and connectors used in the industry.


Comparing Industrial Ethernet Protocols

Comparing Industrial Ethernet Protocols

This article reviews and compares some of the most prominent industrial Ethernet protocols.


Lock-out-tag-out (LOTO) Devices for Industrial Safety

Lock-out-tag-out (LOTO) Devices for Industrial Safety

One of the most visible elements of industrial safety is the use of lock-out-tag-out (LOTO) devices, familiar to those with experience. But, if you are new to the workforce, a brief introduction may be helpful.


Process Noise Sources and How to Fix Them

Process Noise Sources and How to Fix Them

Noise signal sources occur primarily from radiofrequency interference (RFI), often in the form of impulse functions or arcing. How do you mitigate process noise from your control system?


An Overview of Power Over Ethernet (PoE) and Its Use in Industrial Applications

An Overview of Power Over Ethernet (PoE) and Its Use in Industrial Applications

What is Power over Ethernet (PoE), how does it work, and how can industrial facilities benefit?


Introduction to Smart Sensors

Introduction to Smart Sensors

Smart sensors differ from traditional sensors in that they offer benefits such as self-diagnostics, simplified wiring and communication, and more efficient remote monitoring.