Latest Electrical Power Control Technical Articles

Categories

Reversing the Rotation of an Industrial 3-Phase Motor

Reversing the Rotation of an Industrial 3-Phase Motor

Many online sources explain how to reverse a 3-phase motor; this article will discuss the electrical principles that define why it works and how the phase relationships determine the rotation direction.


Motion Control: It’s More Than Just “Point A to Point B”

Motion Control: It’s More Than Just “Point A to Point B”

Building precise rotating or linear systems often costs a lot! When is it justified to spend the extra cost to design and build such a system, and what are the different components and system types?


The Beginner’s Guide to Automation: Maintaining Your System

The Beginner’s Guide to Automation: Maintaining Your System

It's important to keep your system up and running without regular intervention. While every system requires maintenance, never overlook the critical importance of tools and training for the operators.


Converting DC to AC: Basic Principles of Inverters

Converting DC to AC: Basic Principles of Inverters

This article investigates the basic principles of inverters, different types of DC-to-AC conversion, and common applications for generating AC voltage in manufacturing.


Too Much Current! Breaker Curves and Overload Trip Classes

Too Much Current! Breaker Curves and Overload Trip Classes

We know what a circuit breaker is meant to do: stop the flow of electricity in case of a fault or failure. But just like fuses, breakers and overloads respond differently depending on the load.


How to Wire Motor Starters and Contactors

How to Wire Motor Starters and Contactors

This article investigates the basic components and wiring conventions for common three-phase motor starter configurations, including direct online, reversing, and star-delta.


Motor Starter Wiring Infographic

Motor Starter Wiring Infographic

Complete wiring guide for 3-phase motor starters with and without overload (OL) relays.


UDW Data Calculations, Post Disturbance Review, UI, and Backup | Part 2

UDW Data Calculations, Post Disturbance Review, UI, and Backup | Part 2

Effectively managing data includes processing it after initial collection: performing calculations, reviewing for anomalies, and displaying the data for easier actionable insights.


Relays, Relays, and More Relays: 7 Kinds of Industrial Relays

Relays, Relays, and More Relays: 7 Kinds of Industrial Relays

Have you ever heard of a relay? Of course you have. There are many different kinds, plus hundreds of different trade lingo names. What are some of the most common, and how do we use them?


A Better Fit: Comparing Electrical Systems vs. Pneumatic Systems

A Better Fit: Comparing Electrical Systems vs. Pneumatic Systems

Knowing what kind of control system to use: that’s a question that must be answered before setting up the factory floor. Why would someone choose pneumatic over electrical controls?


Data Model and Functionality of Utility Data Warehouse | UDW Part 1

Data Model and Functionality of Utility Data Warehouse | UDW Part 1

Storing data long-term for recording and reporting purposes is the job of the utility data warehouse, quite different from data-collection processes that optimize systems and predict failures.


Electrical Drawings, Schematics, and Wiring Diagrams: How to Read Them

Electrical Drawings, Schematics, and Wiring Diagrams: How to Read Them

In order to trace control system problems to the core, the ability to read and interpret various resources, from facility-level diagrams to machine-level wiring layouts, is critical.


What is a Soft Start? Reducing Start-up Load on Motor Circuits

What is a Soft Start? Reducing Start-up Load on Motor Circuits

Controlling the startup of a motor not only reduces the wear on the motor, but eases the burden on the electrical supply, reducing infrastructure demands and the running cost of industrial loads.


What is a Fuse? The Skinny On Overcurrent Protection

What is a Fuse? The Skinny On Overcurrent Protection

Protecting equipment and personnel from overcurrent dangers, like sparks and fires, is the primary job of the humble fuse, one of the most basic, yet critical of all safety devices.


Data Flow Tutorial With Mage.ai | Part 6: Refined Data Presentation

Data Flow Tutorial With Mage.ai | Part 6: Refined Data Presentation

We conclude the data flow project with the step of developing a business intelligence dashboard to present machine data, at a reliable schedule, to a leadership or maintenance team.


Star-Delta Wiring for Reduced Voltage Starting of 3-Phase Motors

Star-Delta Wiring for Reduced Voltage Starting of 3-Phase Motors

Digital controls like VFDs and soft starts have advantages by elongating start time, but simple strategies for starting motors with a reduced current draw, like star-delta (or wye-delta) are common.


What is a Circuit Breaker?

What is a Circuit Breaker?

We depend on circuit breakers all the time, even when you have a day off or work from home. These overcurrent protection devices keep machines running safely, reducing the risk of fires and arcing.


Handling of Power System Data | Indications, Counters, and Data Flags

Handling of Power System Data | Indications, Counters, and Data Flags

For large process systems, learn how the location of data indication and flag processing can increase or decrease the burden on computers at the device, RTU, or main computer level.


Info Byte: What Do NC and NO Mean?

Info Byte: What Do NC and NO Mean?

Some terminology, like 'normally open' and 'normally closed' switch contacts, is common throughout industry but can still be confusing, misleading, or even hazardous if not properly understood.


Handling of Power System Data: Engineering Limits and Data Currency

Handling of Power System Data: Engineering Limits and Data Currency

Power systems rely on meaningful data, as do most other processes. Within SCADA environments, individual data points are tracked, compared to limits, and evaluated to obtain current readings.